SACMI PCR Series

SACMI PCR Calibration & Backup Plates

Precision Thickness Control · Precision Machined · ±0.05mm Tolerance

📏±0.05mm Precision
⚙️Alloy Steel Material
🔧Fast Delivery

Product Categories

Calibration Plate vs Backup Plate

📐

Calibration Plate

Precision component installed inside the press to set and calibrate slab thickness, ensuring consistent product quality.

  • Directly determines slab thickness accuracy
  • Requires high hardness and wear resistance
  • Regular inspection and replacement needed
🛡️

Backup Plate

Installed below the calibration plate to provide support and cushioning, protecting and extending calibration plate life.

  • Supports and protects calibration plate
  • Distributes pressure, reduces deformation
  • Lower replacement frequency

Compatible Models

Fits All SACMI Continua+ Series

PCR2120

Narrow format, 750-1200mm pressing width

PCR2180

Large format, 1200-1800mm pressing width

PCR3000

Thick slab, 3-30mm thickness range

Technical Specifications

Precision Machined · Strict Quality Control

Product TypePositionDimensions(mm)Thickness(mm)MaterialTolerancePrice
Upper Calibration PlateUpper1960×3908.1Alloy Steel±0.05Inquiry
Lower Calibration PlateLower2100×3808.1Alloy Steel±0.05Inquiry
Upper Backup PlateUpper1960×3908.1Alloy Steel±0.05Inquiry
Lower Backup PlateLower2100×3808.1Alloy Steel±0.05Inquiry

* Above specifications are for PCR2000. Other models vary. Contact technical team for details

Selection Guide

When to Replace · How to Select

When to Replace Calibration Plate

  • 📊 Slab thickness shows significant deviation beyond tolerance
  • 🔍 Visible wear, scratches, or deformation on surface
  • 📏 Accuracy drops during regular calibration
  • ⚠️ Typical replacement cycle: 1-2 years (varies by usage)

Calibration Plate vs Backup Plate

  • Position: Calibration plate is inner layer (direct contact), backup plate is outer layer (support)
  • Replacement Frequency: Calibration plate needs more frequent replacement
  • Price: Calibration plate is relatively higher priced
  • Recommendation: Check backup plate condition when replacing calibration plate

Frequently Asked Questions

Common questions about calibration plate procurement

Can calibration plates and backup plates be purchased separately?

+

Yes, they can be purchased separately. However, we recommend checking backup plate condition when replacing calibration plates and replacing both if necessary to ensure optimal fit and accuracy.

What is the thickness tolerance?

+

GDNOS calibration plates have a thickness tolerance of ±0.05mm, manufactured with precision machining to ensure every product meets accuracy requirements.

How to tell if calibration plate needs replacement?

+

Check: 1) Systematic deviation in slab thickness; 2) Visible wear or scratches; 3) Accuracy drop during calibration. We recommend establishing a regular inspection system.

What is the delivery time?

+

Common specifications are in stock, usually delivered within 1-2 weeks. Custom specifications will be confirmed based on actual situation.

Get Custom Sizing

Tell us your machine model and requirements for the best solution